ECUT 400S PLUS electrosurgical unit by STERNMED.
Features
Twin operative activity
- Two output channels for monopolar cutting
- Two independent setting and output channels for the most frequent monopolar coagulation
Controlled cutting procedures
- Automatic power or TACS (Tissue Adaptive Contact System)
- Enhanced cutting current for eschar free incision
- Cutting current with selectable coagulating property for bleeding controlled dissection
- Low capacitive coupling by slow BLEND current for endoscopic procedures
Twin controlled coagulative procedures
- SPEEDY coagulation and DEEP coagulation available to two operators
- SPRAY coagulation available by hand switch or foot switch controls
Wide bipolar features
- Bipolar cutting current with selectable bleeding control
- Slow BLEND cutting current
- Separately activable Automatic Start/Stop coagulation
- Vessel Sealing up to 7mm
Surgeon and patient total safety
- Acceptability of contact impedance between patient body and return electrode continuously watched by Skin Plate Electronic Control (SPEC)
- H.F. Leakage currents continuously monitored
- Mains fluctuation automatically compensated before to start the delivery of HF power
Accessories
Standard accessories
- Disposable handle with switches
- Reusable handle with switches
- Blade electrode 7 cm
- Blade electrode 16 cm
- Needle electrode 7 cm
- Ball electrode 6 cm
- Cable for neutral electrode
- Disposable split neutral electrode
- Electrode cleaning sponge
- Double water-proof foot-switch
- Power supply cable 5 m
- Cable for neutral electrode
- Disposable split neutral electrode
- Electrode cleaning sponge
- Double water-proof foot-switch
- Power supply cable 5 m
Optional accessories
- Reusable handle without finger switches
- Steel neutral electrode 16x24cm with cable 3m
- Steel neutral electrode 16x24cm autoclave with cable
- Cable for neutral plate
- Bipolar Cable EU 3m
- Twin Bipolar Cable 3m
- Bipolar artery sealer forceps cable
- Disposable Neutral electrode
- Bipolar Artery Sealer 27cm TIP 3mm
- Bipolar Artery Sealer 25,5cm TIP 3mm
- Bipolar Artery Sealer 17cm TIP 2mm
- Blade Curved Electrode 7 cm
- Needle Curved Electrode 7 cm
- Needle Electrode 13 cm
- Ball Electrode Ø 2mm 6 cm
- Ball Curved Electrode Ø 2mm 5 cm
- Ball Electrode Ø 3mm 6 cm
- Ball Curved Electrode Ø 3mm 5 cm
- Ball Electrode Ø 3mm 13 cm
- Ball Curved Electrode Ø 4mm 6 cm
- Ball Electrode Ø 5mm 6 cm
- Ball Curved Electrode Ø 5mm 6 cm
- Ball Electrode Ø 5mm 14 cm
- Loop Electrode10x10 l.14 cm
- Loop Electrode20x13 l.14 cm
- Loop Electrode20x20 l.15 cm
- Conization Electrode 13 cm
- Monopolar cable m4-f4
- Monopolar cable m4-f2.8
- Monopolar cable m4-mp4
- Bipolar Forceps 11,5cm TIP0.5mm
- Curved Bipolar Forceps 11,5cm TIP0.5mm
- Bipolar Forceps 20cm TIP 1mm
- Bipolar Forceps 20cm TIP 2mm
- Curved Bipolar Forceps 20cm TIP 1mm
- Curved Bipolar Forceps 20cm TIP 2mm
- Angled Bipolar Forceps 20cm TIP 1mm
- Angled Bipolar Forceps 20cm TIP 2mm
- Angled Curved Bipolar Forceps 20cm TIP 1mm
- Angled Curved Bipolar Forceps 20cm TIP 1mm
- Bipolar Electrode 20cm
- Monopolar Forceps 20cm TIP2mm
- Monopolar Surgical Scissors 18cm
- Conductive rubber neutral electrode
- Conductive rubber split neutral electrode
- Trolley 3 shelves wide
- Trolley 5 shelves wide
- Drawer for trolley
Specifications
Allgemeines | ||
Patientenkreislauf | F | |
Wählbare Eingangsspannung | 115 – 230 Vac | |
Netzfrequenz | 50–60 Hz | |
Elektrische Leistungsaufnahme | 1000 VA | |
Maße | 470x150x400 BxHxT mm | |
Gewicht | 17,5 kg | |
Bedienelemente | ||
Automatische Stromversorgung oder TACS – Tissue Adaptive Contact System) | Monopolarer CUT-Modus bis 100 Watt | |
Bedienelemente | Überwachung des Patienten-/Plattenkreislaufs | |
Überwachung der Ausgangsleistung | ||
Automatischer Selbsttest | ||
HF-Leckstromregelung | ||
Ausgleich von Netzschwankungen | ||
Leistungsausgänge | ||
Maximale Ausgangsleistung monopolarer reiner Schnitt (CUT) | 400 W – 300 Ω | |
Maximale Ausgangsleistung monopolarer Schnitt-Koag. CUT80% | 300 W – 300 Ω | |
Maximale Ausgangsleistung monopolarer Schnitt-Koag. CUT60% | 250 W – 300 Ω | |
Maximale Ausgangsleistung monopolarer Schnitt-Koag. CUT40% | 200 W – 300 Ω | |
Maximale Ausgangsleistung monopolarer Schnitt ENHANCED | 250 W – 500 Ω | |
Maximale Ausgangsleistung monopolarer Schnitt-Koag. BLEND | 250 W – 300 Ω | |
Maximale Ausgangsleistung monopolare Koag. SPEEDY | 120 W – 500 Ω | |
Maximale Ausgangsleistung monopolare Koag. DEEP | 120 W – 200 Ω | |
Maximale Ausgangsleistung monopolare Koag. SPRAY | 100 W – 2000 Ω | |
Maximale Ausgangsleistung monopolare Koag. SPRAY ARGON | 100 W – 2000 Ω | |
Maximale Ausgangsleistung bipolarer CUT | 120 W – 50 Ω | |
Maximale Ausgangsleistung bipolarer Schnitt-Koag. CUT80% | 120 W – 50 Ω | |
Maximale Ausgangsleistung bipolarer Schnitt-Koag. CUT60% | 120 W – 50 Ω | |
Maximale Ausgangsleistung bipolarer Schnitt-Koag. CUT40% | 100 W – 50 Ω | |
Maximale Ausgangsleistung bipolarer Schnitt-Koag. BLEND | 120 W – 50 Ω | |
Maximale Ausgangsleistung bipolare Koag. COAG. | 120 W – 50 Ω | |
Maximale Ausgangsleistung bipolare Koag. VESSEL SEALING | 250 W – 500 Ω | |
Arbeitsfrequenz Monopolar / Bipolar | 425 kHz / 525 kHz |
Reviews
There are no reviews yet.